Cold-Formed Steel Steel Sheathed Shear Wall Panel examples

From OpenSeesWiki
Jump to navigation Jump to search

In order to check the accuracy of the proposed models, results from quasi-static non-linear analyses of Steel-Sheathed Cold-Formed Steel Shear Wall Panel have been carried out using CFSSSWP uniaxialMaterial model implemented into OpenSees version 2.4.6. For this purpose, specimens 1C-b and 3C-a tested by Balh (2010) were selected from the literature and analyzed under similar loading conditions. This set of specimens covers a wide range of variation in physical and mechanical characteristics such as: spacing, number, shear strength, diameter of screw fasteners (sc, nc, Vs, and ds); wall aspect ratio (H/W); frame thickness, chord stud moment of inertia, chord stud cross section area, interior stud moment of inertia, yield and tensile strengths of steel frame (tf, Af, Ife, Ifi, fyf, and fuf); sheathing thickness, yield and tensile strengths of sheathing (type, ts, Fys, and Fus); as well as the anchor bolt diameter of the HoldDown system (dt).

Each SWP was subjected to the Consortium of Universities for Research in Earthquake Engineering (CUREE) loading protocol.


TCL FILES:

1Cbn.tcl

3Can.tcl

procRCycDAns.tcl


uniaxialMaterial CFSSSWP 1 2440 1220 346 396 1.14 436.22 395 300 0.46 1 4.166 1560 150 22.2 0 0

Fig 1. Comparison between steel sheathed CFS SWP experimental and numerical results specimens No 1C-b


uniaxialMaterial CFSSSWP 2 2440 1220 391 342 0.87 436.22 395 300 0.46 1 4.166 1560 150 22.2 0 0

Fig 2. Comparison between steel sheathed CFS SWP experimental and numerical results specimens No 3C-a

REFERENCES:

Smail Kechidi and Nouredine Bourahla, Deteriorating hysteresis model for cold-formed steel shear wall panel based on its physical and mechanical characteristics, Journal of Thin-Walled Structures (2016), pp.421-430. DOI:10.1016/j.tws.2015.09.022.

Smail Kechidi, Hysteresis model development for cold-formed steel shear wall panel based on physical and mechanical characteristics, Master Thesis, University of Blida 1, Algeria, 2014.

Smail Kechidi and N Bourahla, Deteriorating hysteresis model for cold-formed steel shear wall panel based on physical and mechanical characteristics, OpenSees Days Portugal 2014- OPD 2014, 3-4 July 2014, Porto, Portugal.

L.N. Lowes, A. Altoontash, Modelling reinforced-concrete beam-column joints subjected to cyclic loading, Journal of Structural Engineering, 129(12):1686-1697, 2003.

Yanagi N, Yu C. Effective strip method for the design of cold-formed steel framed shear wall with steel sheet sheathing. Journal of Structural Engineering, ASCE 2014; 140(4).

Nisreen Balh, Development of seismic design provisions for steel sheathed shear walls, Master Thesis, McGill University, Canada, 2010.


Code Developed by: Smail Kechidi and Nouredine Bourahla, University of Blida 1, Algeria

Images Developed by: Smail Kechidi, University of Blida 1, Algeria


Authors contact:

Smail Kechidi, PhD student at University of Blida 1, Algeria, s_kechidi@univ-blida.dz, skechidi@yahoo.com

Nouredine Bourahla, Professor at University of Blida 1, Algeria, nbourahla@univ-blida.dz