This command is used to construct a Newmark integrator object.
integrator LoadControl $lambda <$numIter $minIter $maxIter> |
$lambda | <math>\lambda</math> factor |
$numIter | the number of iterations the user would like to occur in the solution algorithm. Optional, default = 1.0. |
$minLambda | the min stepsize the user will allow. optional, defualt = <math>\lambda_{min} = \lambda</math> |
$maxLambda | the max stepsize the user will allow. optional, default = <math>\lambda_{max} = \lambda</math> |
NOTES: The change in applied loads that this causes depends on the active load patterns (those load patterns not set constant) and the loads in the load patterns. If the only active loads acting on the domain are in load patterns with a Linear time series with a factor of 1.0, this integrator is the same as the classical load control method.
EXAMPLE:
integrator LoadControl 0.1;
THEORY:
In Load Control the time in the domain is set to <math>t + \lambda_{t+1}</math> where,
- <math> \lambda_{t+1} = \max \left ( \lambda_{min}, \min \left ( \lambda_{max}, \frac{\text{numIter}}{\text{lastNumIter}} \lambda_{t} \right ) \right ) </math>
Code Developed by: fmk